Leuze electronic Safety Notices
Leuze electronic BPS 37 5
TNT 35/7-24V
2 Safety Notices
2.1 Safety Standards
The barcode positioning system BPS 37 and the optional connection units MA 4.7/MA 4D.7
have been developed, produced and tested subject to the applicable safety standards. They
correspond to the state of the art.
2.2 Intended Use
Attention!
The protection of personnel and the device cannot be guaranteed if the device is operated
in a manner not corresponding to its intended use.
Barcode positioning systems of the type BPS 37 are optical measuring systems which use
visible red laser light to determine the position of the BPS relative to a permanently mounted
barcode band.
Typically, the BPS is mounted on a (rail-)guided vehicle whose position is to be exactly
determined.
The position is determined to within a millimetre using the information of the fixed barcode
band and made available to the primary system at a suitable interface.
The optional connector and interface units MA 4.7/MA 4D.7 are intended for the easy
connection of barcode positioning systems of type BPS 37.
In particular, unauthorised uses include:
rooms with explosive atmospheres
operation for medical purposes
Areas of application
The barcode positioning system BPS 37 with optional connection unit MA 4.7/MA 4D.7 has
been designed particularly for the following fields of application:
High-bay storage devices and lifting gear
Crane systems
Side-tracking skates
Transfer machines
Telpher lines
Vista de pagina 6