Leuze electronic Installation
Leuze electronic BPS 37 25
TNT 35/7-24V
6.3.3 Connection of switching input and output
The BPS 37 is provided with a switching input and a switching output. The connection of the
switching input and output is made according to figure 6.7:
Figure 6.7: Connection diagram switching inputs and outputs BPS 37
Switching input
In the standard setting you can use the switching input connection SWIN1 to reset the output
of the position measurement data to zero by applying a voltage of 12 … 30VDC between
SWIN1 (pin 2) and GND (pin 15).
Switching output
The switching output connection between SWOUT1 (pin 10) and GND (pin 15) is normally
open. In the standard setting, SWOUT1 is closed in the event of a positioning error.
You can configure the switching inputs and outputs according to your needs, using the
supplied BPSConfig program.
10 … 30 V
DC
12 … 30 V DC
SWIN12
SWOUT110
GND15
VIN8
max. 100 mA