Leuze electronic Installation
Leuze electronic BPS 37 23
TNT 35/7-24V
Wiring description
Table 6.1: Connection description BPS 37
6.3.2 Connection SSI interface
Connection with MA
Figure 6.5: Connection with MA
Pin 1 GND Ground reference RS 232
Pin 2 SWIN1 Switching input 1 (+12 … 30VDC)
Pin 3 SSI data+ SSI data line
Pin 4 SSI data- SSI data line
Pin 5 Reserve
Pin 6 SSI clock+ SSI clock line
Pin 7 /Serv Bridge to pin 15: service operation via RS232 interface
Pin 8 VIN Supply voltage +10 … 30VDC
Pin 9 SSI clock- SSI clock line
Pin 10 SWOUT1 Switching output 1 (max. 100mA)
Pin 11 RXD/Serv RXD signal, service interface RS 232
Pin 12 TXD/Serv TXD signal, service interface RS 232
Pin 13 Reserve
Pin 14 Reserve
Pin 15 GND Supply voltage 0VDC
SSI DATA +
SSI DATA -
SSI Clock +
SSI Clock -
SSI DATA +
SSI DATA -
SSI Clock +
SSI Clock -
1/2
3/4
13
7
MA 4.7/MA 4D.7 Control/drive